Multiple Dwellings ch 1-5 Flashcards
A fire partition has a fire resistive rating of ____ hours
At least 3 hours
T or F
The 2nd arriving OV secured a 2nd fireman service elevator and worked in conjunction with the first arriving OV
True. 6.3.2 B
A fire wall has a fire resistive rating of ____ hours
At least 4 hours
Who picks the attack stairway at a high rise MD?
1st arriving ladder after consulting with the first engine officer
Who brings the KO curtain to the floor above ?
1st and 3rd due roof
Describe OLTs built before 4/12/01
3-7 stories, 20-25 feet wide
-50-85 feet deep
-2 means of egress from each apt ie interior stairs and fire escape
-2-4 apts per floor
May find steel steel H columns and steel I beams in RENOVATED OLTS
In 1934 , most OLTS were required to fire retard the stairway enclosure
Describe NLTS built after 4/12/01 and before 1916?
- Generally 6 or 7 stories high
- 35 to 50 feet wide, 85’ in depth
- 5- 6 apts per floor
- Cellar ceiling is fireproof
- entrance via exterior
- all interior walls and furred partitions are fire stopped at each story
- steel I beams found, generally supported by masonry walls
Newer types of NLTS were built between 1916-1929. To avoid being required to be built with fireproof construction, the floor areas were broken up into units of _____ square feet or less
2500
Note: newer NLTS ( H types) can be as large as 150’ x 200’
- entrance to bsmt is by side or rear door at that level via exterior stair from the first floor OR through a passageway in the front of the bldg
How high to the fireproof partitions go in newer NLTS built between 1916-1929?
Only as high as the ceiling of the top floor
Between 1930 and 1940, firewalls were required to be carried to the?
Underside of the roof boards
After 1940 ie 1941 and thereafter, firewalls were required to go to?
The top of the roof boards
After 4/18/1929, class “A” apartment houses were required to be enclosed by fire walls _______ square feet or less
3000
A hoseline on the roof of a NFP md should be used to do what 3 things?
- Prevent fire from extending past the trench
- protect exposures
- extinguish fire that can’t be reached from below such as fire in the cornice
The primary use of first Hoseline at a NFP MD is to?
Safeguard the stairs so that it can be used by escaping occupants
No materials shall be thrown onto roofs of setbacks or into _____ shafts
Narrow
If possible when cutting roof at a NFP MD, the ____ side of the opening should be at ______ angles to the roof beams in order to provide venting of as many bays as possible
If possible, the long side of the opening should be at right angles to the roof beams in order to provide venting of as many bays as possible
Fire on two floors in an OLT or NLT, the IC shall?
Special call an engine and truck
If progress is not made on at least one floor in a short period of time, the IC shall?
Transmit 2nd alarm
MDs 3.4.4