Multiple Dwellings ch 1-5 Flashcards

0
Q

A fire partition has a fire resistive rating of ____ hours

A

At least 3 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
0
Q

T or F

The 2nd arriving OV secured a 2nd fireman service elevator and worked in conjunction with the first arriving OV

A

True. 6.3.2 B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
0
Q

A fire wall has a fire resistive rating of ____ hours

A

At least 4 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

Who picks the attack stairway at a high rise MD?

A

1st arriving ladder after consulting with the first engine officer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Who brings the KO curtain to the floor above ?

A

1st and 3rd due roof

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Describe OLTs built before 4/12/01

A

3-7 stories, 20-25 feet wide
-50-85 feet deep
-2 means of egress from each apt ie interior stairs and fire escape
-2-4 apts per floor
May find steel steel H columns and steel I beams in RENOVATED OLTS
In 1934 , most OLTS were required to fire retard the stairway enclosure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Describe NLTS built after 4/12/01 and before 1916?

A
  • Generally 6 or 7 stories high
  • 35 to 50 feet wide, 85’ in depth
  • 5- 6 apts per floor
  • Cellar ceiling is fireproof
  • entrance via exterior
  • all interior walls and furred partitions are fire stopped at each story
  • steel I beams found, generally supported by masonry walls
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Newer types of NLTS were built between 1916-1929. To avoid being required to be built with fireproof construction, the floor areas were broken up into units of _____ square feet or less

A

2500
Note: newer NLTS ( H types) can be as large as 150’ x 200’
- entrance to bsmt is by side or rear door at that level via exterior stair from the first floor OR through a passageway in the front of the bldg

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How high to the fireproof partitions go in newer NLTS built between 1916-1929?

A

Only as high as the ceiling of the top floor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Between 1930 and 1940, firewalls were required to be carried to the?

A

Underside of the roof boards

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

After 1940 ie 1941 and thereafter, firewalls were required to go to?

A

The top of the roof boards

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

After 4/18/1929, class “A” apartment houses were required to be enclosed by fire walls _______ square feet or less

A

3000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

A hoseline on the roof of a NFP md should be used to do what 3 things?

A
  • Prevent fire from extending past the trench
  • protect exposures
  • extinguish fire that can’t be reached from below such as fire in the cornice
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The primary use of first Hoseline at a NFP MD is to?

A

Safeguard the stairs so that it can be used by escaping occupants

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

No materials shall be thrown onto roofs of setbacks or into _____ shafts

A

Narrow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

If possible when cutting roof at a NFP MD, the ____ side of the opening should be at ______ angles to the roof beams in order to provide venting of as many bays as possible

A

If possible, the long side of the opening should be at right angles to the roof beams in order to provide venting of as many bays as possible

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Fire on two floors in an OLT or NLT, the IC shall?

A

Special call an engine and truck

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

If progress is not made on at least one floor in a short period of time, the IC shall?

A

Transmit 2nd alarm

MDs 3.4.4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Store fires in OLTs according to the MD bulletin states that a 2 1/2 inch line SHOULD be stretched for _______ volume fires and a 2nd line stretched to the entrance hallway

A

LARGE

Note: when assured that the 2nd line is not needed on the first floor it may be advanced to the floor above the fire

16
Q

T or F. MDs 4.2.2 store fires
A charged Hoseline MUST be ready before the store is ventilated. No plate glass windows are to be broken without a charged handline being ready

A

True

17
Q

T or F
For fires in rooms in the vicinity of a shaft at a MD, after the fire in the room has been controlled, the line should be operated up the shaft to extinguish fire and cool the shaft

A

True

18
Q

Collapse of floors at OLTS is usually not a problem according to the MD bulletin because of the short span of floor beams, _____ feet

A

25 feet

19
Q

Buildings in the rear of OLTs are usually not seriously exposed because they are anywhere from ____ to _____ feet or more away from the OLT

A

10 to 25 feet or more away from the OLT

20
Q

T or F.
OLTs that were converted to SROs require sprinklers in each room and in the stairway. The sprinkler is city main fed and cannot be supplied by the fire department

A

True
Note: these sros also require an interior alarm system to warn the occupants of fire. Exit lights and signs must be provided

21
Q

Who must the roof ff inform of party wall balconies being in the rear of a MD?

A

His officer and the IC

22
Q

In class “A” NFP MDs built after 4/12/01 to the present, the most common roof has the top floor ceiling _______ feet below the main roof beams

A

Several
Note: the roof boards are fastened directly to the top of the roof beams This provides for a sturdy roof
5.1.1 D 2

23
Q

H types

If the roof man notices the waste pipes are hot to the touch, who must he notify?

A

His officer and the IC
Note: a top floor examination is required
Note: He doesn’t use an ungloved hand when feeling for heat

24
Q

What is the primary means of getting to the roof in an H type?

A

Winged or isolated stairs in the same building or the adjoining building if feasible
Mds 5.2.2

25
Q

The IC should call for ______ for a medium fire at an H type when it is anticipated that 2 lines will be required

A

Extra engine and truck

26
Q

If two floors are involved at an H type ?

A

It will be generally necessary to transmit a 2nd alarm

Note: 2nd alarm for extensive cockloft fire

27
Q

According to the picture in figure 6 in MDs the dimensions of H types can be as large as ___ x _____ feet

A

60x 340 feet, 6 stories, 22 apts per floor

28
Q

At store fires in MDs, where does the 2nd line operate?

A

Backs up the first line. When it is OBVIOUS that first line can CONTROL the store fire, the 2nd line should be advanced to the floor above
5.3.1 B 2

29
Q

Cellar fires in class A NFP MDs built after 1901 have a ____ hour fire resistance for the concrete cellar ceiling

A

2

30
Q

In an H type, how does first line advance to a cellar fire?

A

By way of the usually numerous exterior approaches to the seat of the fire

31
Q

H type cellar fire, roof man goes to roof and does what?

A

Vent and examination . He also checks cockloft for possible extension of fire through vertical voids

32
Q

Will a roof sector supv be assigned to the roof of an H type for a top floor fire?

A

Yes. IC will designate a co officer as roof supv until a chief can be assigned. Once a roof sector supv is assigned, all communications between roof and IC go through roof supv.

33
Q

When trenching at an H type, how many inspection holes shall be made?

A

Two or more on the fire side of the trench. When fire reaches the inspection holes, the precut trench is pulled

34
Q

The trench should be cut about _____ feet from the initial vent hole

A

20

35
Q

Can a line be operated into a trench?

A

A line may be operated into the trench in a brief sweeping side to side motion to prevent fire from extending

36
Q

T or F
At times it may be necessary to assign engine co’s OR individual engine FFs to pull ceilings when fire in cockloft at an H type

A

True

37
Q

Some cockloft are as much as ____ feet deep in H type buildings

A

4

Page 33

38
Q

The most probable point for vertical fire extension at an H type will be?

A

Vertical steel channels ( in buildings that have steel frame construction)
5.3.4

39
Q

Fire in channel rails in H types necessitates opening up where?

A

Opening up above and at the top floor ceiling for extension into the cockloft

40
Q

T or F
If heavy fire conditions exist on a floor in an H type, the area and the base of any shafts below the fire must be examined for extension

A

True

41
Q

When transmitting 2nd or greater alarms for cockloft fires in large H type buildings, the IC should?

A

CONSIDER calling additional BC’s to cover critical sectors and/or exposures . Eg top floor sector supv, roof sector supv