Volume 4 PTQ 1 Flashcards Preview

Volume 4 > Volume 4 PTQ 1 > Flashcards

Flashcards in Volume 4 PTQ 1 Deck (34)
Loading flashcards...
1

Departmental training committee: all________ of the department

Assistant fire chief's

2

Captains shall: if assigned to a fire station conduct a______ hour drill each shift and______ wet apparatus drills each month

TWO
TWO

3

Scope of training: there are five general areas of training which comprises the department training plan

1) chief/Company officer
2) tower/In-service
3) firestation
4) recruit
5) technical

4

Tower/In-service training is mandatory and each company shall drill as a unit at a departmental approved training site a minimum of_____hours per year______ three hour sessions (I SO requirement)

18
6

5

At least one safety drill shall be conducted each month and last a minimum of_____hour

1

6

_________ Shall maintain a stock of library material published by other organizations or agencies for distribution

Training services section

7

Arial supply line:___Inch hose with____ inch couplings. 100 foot length

3
2 1/2

8

Water shall be run through all hose once every____ unless the hose has been otherwise wet in-service

Three months

9

All rubber hose must be reloaded following the annual hose test and then__________ thereafter

Quarterly

10

_______ shall assign new hose numbers

The property inventory unit of the administrative bureau located at Pacoima warehouse

11

Hard suction hose shall be marked with the______ number, And engine______ number

Vehicle identification
Company

12

Standard loads of 4 inch hose and compliment for standard engine

800 load and 900, complement

13

Standard load of 2 1/2 inch hose and complement for a standard engine

800 and 900

14

Standard load of 1 3/4 inch hose and compliment for a standard engine

750 and 1000

15

Standard load of 2 1/2 inch hose and complement for a quint

400 and 600

16

The total length of any holes line in the test layout shall not exceed______

300 feet

17

When testing hose all personnel so clear the area at minimum distance of______ feet, other than those required to perform the remainder of the procedure. The pressure shall be increased slowly to the service test pressure and held within plus or minus_____ PSI

15 feet

5 PSI

18

Annual test pressure: The standard hose test pressure is_____ PSI for all hose except otherwise specified

300 psi

19

All bypass and soft suction and rubber nitrile hose shall be tested a_______

250 psi

20

All hard suction hose shall be tested at_____ PSI

100 psi

21

For 50' sections,_____ is the minimum allowable length for use in the field

35 feet

22

For 100 foot sections_______ is the minimal allowable late for use in the field

70 feet

23

For 20 foot bypass and soft suctions______ feat is the minimum allowable length

12 feet

24

Whenever the hose length falls below the minimum allowable length, initiate a

Survey request form 41

25

Use_______ around the hose one inch from the damage and then with a grease pencil or felt that pen to circle the damaged area. Do not use rags or springs to indicate these areas

Duct tape

26

Connecting to sprinkler or stamp pipe systems on systems with inlet in a vertical position, connect to the______ first

Lower

27

The load limit for roof ladders, supported is______

One person every other wrong

28

The load limit for extension ladder 35 foot is

Four personnel

29

Lifeline specifications:

1/2 inch static Kernmantle
100% nylon
Elongation 2% to 200 lbs, 17% at 75% of min. Breaking strength less than 20% at failure
Melts at 480– 500, becomes sticky at 445, yellows at 300 after five hours of exposure
Braid: One over and one under
Core: continuous, Block creel construction

30

Lifelines shall be inspected and inventoried______ and noted on form_____

Monthly
Form 248, rope system inventory