scba Flashcards
Regulator controls pressure to what?
Slightly above atmospheric
Pra reduced to what psi?
100 psi
Failure of the primary system directs air to a secondary system reduced to?
150 psi. Vibra alert goes off, must notify off and leave area with another member using scba.
Failure of both the primary and secondary system in the open position will activate a reliever valve in the pra, which will discharge all pressure in excess of?
185 psi into atmosphere. When this occurs the cylinder valve should be partially closed. Member must notify off and leave paired up. ( doesn’t say anything about vibes alert)
A 45 min cylinder can be deleted in how long if if manual shut off switch is not pressed?
4 minutes
If manual shut off fails to release turn the purge valve_____, ___ degrees
Downward, 180 degrees. Notify off and leave with scba member
Failure of the regulator on the closed position (no air to face piece), what do u do?
Turn purge valve counter clockwise.
Failure to regulator in the open position (to much airflow), what do u do?
Open the purge valve fully, and partially close the cylinder valve.