What years were fire towers required ?

A

1938- 1968

Some before 1938 had fire towers
Fire towers no longer required after 1968

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

High pressure engines with third stage capability can supply_____
Gpm at ______ psi ?

A

357 magnum

3rd stage
500 gpm at 700 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Fusible links in fire dampers will automatically close dampers when abnormal rise in temp how many degrees above the max temp that would normally encountered in the HVAC system ?

A

50 degrees above the max temp

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The 1938 building code only requires a manual fire pump in buildings over ______ feet high

A

250

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The 1968 building code requires a manual fire pump to supplement the standpipe system in buildings over _______ feet

A

300 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Correct order to start building fire pumps using control panel?

A

1 close knife switch to on position
2 close circuit breaker and power on light will glow
3 push starting button and pump on light will glow
4 move selector level to desired position increasing pump speed which increases pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Can trucks be a lobby control unit ?

A

No. Comm ch 2 sec 2.12.3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Can engines be assigned as a fast unit ?

A

Yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Stack effect becomes noticeable in buildings _____ feet or more

Negative stack effects possibility is greatest when the outside temp is above____ degrees F

A

60 feet

90 degrees
91 or greater

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Who is specifically responsible besides the IC to ensure that the attack stairway has been cleared of building occupants for at
Least 5 floors above the fire ?

A

Fire Sector supervisor, fire branch director as well as the IC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The lobby control unit is a unit within the ______ section responsible for moving members to and from upper floors

A

Logistics section

Ics ch 2 add 4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What tools does fast truck and cfrd unit bring to fire sector?

A

The cfrd unit brings cfrd equipment and FE tools. Truck brings regular tools

Note: at high rise mds cfrd unit still brings FE tools but truck now brings a set of elevator keys

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Where do cfrd and fast unit stage at HRFP office buildings vs HRFP Mds?

A

At HRFP office buildings they will stage at the fire sector which is most likely the floor below the fire ; conditions permitting.

At HRFP mds if the fire is ABOVE the 6th floor then they will stage at the fire sector usually the floor below the fire floor. If fire on the 6th floor or below go where IC wants u to go.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Can 2nd line be used on floor above at HR office buildings?

A
No, it must be used to:
reinforce first line
Protect first line 
Protect search and evac of fire floor
Contain and confine fire spread and/or prevent fire from wrapping around the core and endangering ops of first line

Note: line can go to floor above at HRFPMDs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Where does 2nd truck operate at HRFP office vs HRfPMDs?

A

HRFP office - 2nd truck stays on fire floor

hRFPMDS- searches fire floor hallway , and then attack stairs for 5 floors above the fire floor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Who searches attack stairs in HRFP office buildings ?

A

3rd truck searches and evacuates floor above as we’ll as the attack stairway for A REASONABLE distance above the fire floor.

16
Q

If height of fire floor requires pressure in excess of 250 psi, who can order higher pressures?

A

The IC if the following conditions are followed:

  • everyone stands clear 50 ft on both sides of the hose line (3” special high pressure hose must ..)
  • utilize warning tape, stanchions or utility ropes
  • B.C. Designated as high pressure group Supv shall control this op
  • audible alert to members, civilians
  • supply line secured to substantial object with UTILITY rope
  • only special high pressure fittings may be used They are painted white and are noticeably heavier
  • maintain 50 ft around engine in all directions
17
Q

When the fire is above the 50th floor (400 psi) or the building water supply is unsatisfactory, it may be necessary to use the third stage of the high pressure engine. Who can order this?

A

Only the IC. ECCS of high pressure engines must ensure that TETHER security ropes are in place prior to activating the third stage of the pump
Note: engine ops ch 9 states only IC who is a chief officer can order 3rd stage

18
Q

8.3.1 E. 4

Who selects attack stairway at a HROB?

A

1st Ladder will select the attack stairway with a standpipe that will provide the best attack on the fire
Note: At high rise FPMD, first due engine consults with first due truck to decide which will be the Attack stairway. The stairway need not be one with a standpipe outlet
Note at LRFPMD w/ 2 enclosed stairs, truck off chooses and notifies engine boss, IC