High Rise Office Buildings Flashcards
What years were fire towers required ?
1938- 1968
Some before 1938 had fire towers
Fire towers no longer required after 1968
High pressure engines with third stage capability can supply_____
Gpm at ______ psi ?
357 magnum
3rd stage
500 gpm at 700 psi
Fusible links in fire dampers will automatically close dampers when abnormal rise in temp how many degrees above the max temp that would normally encountered in the HVAC system ?
50 degrees above the max temp
The 1938 building code only requires a manual fire pump in buildings over ______ feet high
250
The 1968 building code requires a manual fire pump to supplement the standpipe system in buildings over _______ feet
300 feet
Correct order to start building fire pumps using control panel?
1 close knife switch to on position
2 close circuit breaker and power on light will glow
3 push starting button and pump on light will glow
4 move selector level to desired position increasing pump speed which increases pressure
Can trucks be a lobby control unit ?
No. Comm ch 2 sec 2.12.3
Can engines be assigned as a fast unit ?
Yes
Stack effect becomes noticeable in buildings _____ feet or more
Negative stack effects possibility is greatest when the outside temp is above____ degrees F
60 feet
90 degrees
91 or greater
Who is specifically responsible besides the IC to ensure that the attack stairway has been cleared of building occupants for at
Least 5 floors above the fire ?
Fire Sector supervisor, fire branch director as well as the IC
The lobby control unit is a unit within the ______ section responsible for moving members to and from upper floors
Logistics section
Ics ch 2 add 4
What tools does fast truck and cfrd unit bring to fire sector?
The cfrd unit brings cfrd equipment and FE tools. Truck brings regular tools
Note: at high rise mds cfrd unit still brings FE tools but truck now brings a set of elevator keys
Where do cfrd and fast unit stage at HRFP office buildings vs HRFP Mds?
At HRFP office buildings they will stage at the fire sector which is most likely the floor below the fire ; conditions permitting.
At HRFP mds if the fire is ABOVE the 6th floor then they will stage at the fire sector usually the floor below the fire floor. If fire on the 6th floor or below go where IC wants u to go.
Can 2nd line be used on floor above at HR office buildings?
No, it must be used to: reinforce first line Protect first line Protect search and evac of fire floor Contain and confine fire spread and/or prevent fire from wrapping around the core and endangering ops of first line
Note: line can go to floor above at HRFPMDs
Where does 2nd truck operate at HRFP office vs HRfPMDs?
HRFP office - 2nd truck stays on fire floor
hRFPMDS- searches fire floor hallway , and then attack stairs for 5 floors above the fire floor