CORDON SIZE FOR ANY MILITARY EXPLOSIVE MUNITIONS UP TO 2000kg?
600M
CORDON SIZE FOR TERRORIST INCIDENT INVOLVING EXPLOSIVE DEVICE THE SIZE OF A SUITCASE?
MORE THAN 100m
CORDON SIZE FOR TERRORIST INCIDENT INVOLVING EXPLOSIVE DEVICE THE SIZE OF A CAR/LIGHT VEHICLE?
MORE THAN 200m
CORDON SIZE FOR TERRORIST INCIDENT INVOLVING EXPLOSIVE DEVICE THE SIZE OF A HGV/LORRY?
MORE THAN 400m
CORDON SIZE FOR AN ACETYLENE CYLINDER?
200m
INCIDENTS ON ROADWAYS:
- INNER?
- OUTER?
INNER: 2m
OUTER: 5m
CORDON SIZE FOR A LOW PRESSURE DOMESTIC NETWORK GAS LEAK?
25m
CORDON SIZE FOR A HIGH PRESSURE, NTS, LDZ, OR LOCAL DISTRIBUTION CENTRE GAS LEAK?
200m
CORDON SIZE FOR A HIGH PRESSURE, NTS, LDZ, OR LOCAL DISTRIBUTION CENTRE GAS LEAK WHERE THE LEAK IS CONGESTED?
600m
HAZARD ZONE FOR AN UNCONTROLLED LEAK FROM A MASSED STORAGE SITE?
1000m
HAZARD ZONE FOR UP TO 250kg OF EXPLOSIVES/FIREWORKS?
200m
CORDON SIZE FOR UP TO 251-2000kg OF EXPLOSIVES/FIREWORKS AND ALL MILITARY EXPLOSIVE MUNITIONS?
600m
CORDON SIZE FOR OVER 2000kg OF EXPLOSIVES/FIREWORKS?
1000m
SAFE DISTANCE FROM OVERHEAD CABLES WORKING WITH A GROUND MONITOR?
30M CORRIDOR
SAFE DISTANCE FROM OVERHEAD CABLES WORKING WITH A HANDHELD BRANCH?
20M CORRIDOR
SAFE DISTANCE FROM OVERHEAD CABLES WORKING OPERATIONALLY WITHOUT HOSE?
10M CORRIDOR
SAFE DISTANCE FROM OVERHEAD CABLES/SUBSTATIONS/OTHER ELECTRICAL SUPPLY INDUSTRY EQUIPMENT WHEN CARRYING OUT A RESCUE?
5M
SAFE DISTANCE FROM OVERHEAD CABLES WORKING WITH LADDERS/AERIAL APPLIANCES/TALL EQUIPMENT/IN DENSE SMOKE OR FLAMES APPROACHING CONDUCTOR?
10M CORRIDOR
SAFE DISTANCE FROM OVERHEAD CABLES IN A TRAINING SCENARIO?
20M
LFB ELECTRICAL GLOVES ONLY TO BE USED WHEN VOLTAGES ARE KNOWN TO BE LESS THAN?
3300V
HIGH VOLTAGE MEANS?
GREATER THAN 1000V AC or 1500V DC
LOW VOLTAGE MEANS?
LESS THAN 1000V AC or 1500V DC