- What does Positive Pressure Fan do & what can it be used on?
- Natural tendency of air movement
- PPF shall be dispatched on signal _ &
A
- Pressurize attack & evacuation stairwells to keep heat & smoke from entering stairwells or to vent the bldg. Works on smoke & CO
- Higher pressure area to lower pressure area
- 10-77 & special called by IC
2
Q
- The 1st consideration for PPF is _ stairway
- The _ stairwell shall be pressurized when necessary for sequential ventilation
- Can the Vent Support Group Supervisor initiate stairwell pressurization?
A
- Attack Stairway: FFs should be notified via HT & Dispatcher when attack stairs designated
- Evacuation stairs
- No only IC can. Vent Group Supervisor informs IC of recommended placements of PPF
3
Q
- Priority Order for use of PPF (3)
2. Does the PPF in the attack stairwell provide an uncontaminated area of refuge for members?
A
- Pressurizing Attack Stairway to support fire attack throughout attack stairway, Pressurizing Evac stairs for smoke & CO control, & Vent public hallways for smoke & CO control
- Yes
4
Q
- The initial location for PPF should be _
- PPF will be great enough to allow for up to _ stairwell doors to be open & pressurization to remain effective
- 1 fan can provide proper pressure in stairwell up to _ stories & 2 fans will pressurize _ story bldg
A
- Ground floor- try to utilize an exterior door to reduce noise & CO levels for ICP
- Up to 3, but keeping as many doors closed as possible is the goal (even if HL stretched close door as much as possible)
- 10; 40
5
Q
- If units are committed on fire fl but extreme smoke condition of stairwell- PPF can _
A
- Begin pressurization on ground fl w/fire fl door closed as much as possible for HL. Vent Group Roof FF shall burp the bulkhead door open until smoke clears approx 60 sec & shut bulkhead. Pressurization maintains in stairwell w/bulkhead open or closed
6
Q
- If CO levels are in the - ppm range, gas powered PPF will NOT significantly reduce CO levels
- One 27” gas powered fan moves approx _ times more air than 16” electric box fan
A
- 0-60 PPM
2. approx 5 times (24,000 CFM)
7
Q
- What can be used to create Negative Pressurization?
2. Negative pressure is beneficial in _ areas
A
- Lad Cos electric box fan operated in exhaust mode to remove contaminated air
- Below grade areas
8
Q
- Ladder Cos that carry PPF are designated _ & report to _
- The Off of PPF is designated
- The members assigned to operate the fans are designated
A
- Ventilation Support Group Companies; ICP
- Ventilation Group Supervisor
- Ventilation Group Lobby Unit, Vent Group Fire Unit, Roof FF: Vent Group Roof
9
Q
- Once PPF put in operation, can they be left unattended?
5. What if negative results are encountered w/PPF?
A
- Never unattended- HT equipped FF must continually monitor-Dave Clark set
- Discontinue by throttling fans to idle, close stairwell door, & notify IC
10
Q
- Pushing fresh air into areas that need to be pressurized or ventilated is preferred method for positive pressure vent. Optimum placement is _
- The fan should be positioned to blow (into/out) of stairwell & (should/should not) be placed in stairwell
A
- 4-6’ from Attack stairway door on ground floor (NOT in stairway) & directly facing the door to stairwell at an angle tilt of 80 degrees
- Into; Should NOT- may create high CO levels & negative stack effect by pulling smoke & heat
11
Q
- Fire above the _ floor- add’l PPF req’d & set up __
5. Extreme smoke condition in Attack Stairwell (how do you remove)
A
- Above 10th fl; 3 Flrs below & set up same as 1st fan 4-6’ back 80 angle (NOT in stairwell)
- When units NOT committed on fire fl- PPF on ground fl & Vent Roof FF shall open bulkhead (burp) approx 60 sec & shut bulkhead. Stay at bulkhead position
12
Q
- Sequential Ventilation is done after fire extinguished to remove products of combustion vertically through _ by placing a fan at the base of _. Keep he bulkhead of _ stairway open & _ closed. Open stairwell doors on fire floor for _ stairway.
A
- Attack Stair; base of Evac Stairwell; Attack bulkhead open & Evac closed; Both doors to cross vent
13
Q
- Does wind have to be considered when using PPF?
4. Fans blowing fresh exterior air into the structure have shown to be _% more efficient than negative pressure vent.
A
- Yes Wind must ALWAYS be considered
4. 75%
14
Q
- During Negative pressurization, if a box fan cannot be hung or tarps not available, position fan inside contaminated area facing exhaust opening _ feet back tilted _ degrees
- How many FF to lift PPF?
- PPF inspected _
A
- 6-8’ approx 30 degree tilt
- 2 members
- Inspected & started daily 9X6 tour. Weekly at MUD full RPM run for 5 min along w/visual inspection. Repairs to Tech Services