To ensure obstacle clearance while taxiing in a turn:
What is the minimum obstacle clearance required by the wingtip?

4,6 meters

1

What is the minimum width of pavement for a 180 degree turn?

787-8 42,2 meters
787-9 47 meters

2

To ensure obstacle clearance while taxiing in a turn:
What is the minimum obstacle clearance required by the nose?

16,8 meters

3

What is the maximum steering angle when using the tiller?

70 degrees

4

What is the maximum steering angle when using the rudder pedals?

8 degrees

5

When and how can the flight deck overhead door be opened?

Only on the ground with the airplane depressurized

6

What is used to emergency egress from through the flight deck overhead door?

Descent devices

7

When is the flight deck overhead vent door used? How is it opened?

Used to ventilate the flight deck in non-normal situations.
Opened by pulling on the overhead vent handle.

8

What is the aircraft wingspan?

60,1 meters

9

What is the aircraft length?

787-8 - 56,7 meters
787-9 - 62,8 meters

10

What is the aircraft height?

16,9 meters

11

How many units comprise the CCS?

Two CCR cabinets

12

Are there any controls or indications associated with the normal operation of the CCS.

No

13

Loss of all displays is an indication of the failure of what system?

CCR fault

14

Where would you find the "LOSS OF ALL DISPLAYS" checklist?

Unannunciated non-normal checklist in the QRH

15

Can the CCR's be restarted in flight? If so, how long does a restart cycle take?

Yes.
Restart cycle takes approximately 1 minutes for the CCR to begin running.

16

If the CCR's do not restart, what two system failures will affect operational performance of the flight?

Landing gear normal extension
Auto speedbrake

17

If only the battery power is selected on for airplane start-up, which CCR powers up?

Left CCR

18

How long does the CCR take to power up?

Approximately 2-3 minutes

19

If the CCR is in the middle of its start up sequence on battery power, and external power becomes available, what happens to the CCR start up sequence?

The right CCR start up cycle is enabled

20

With forward external power available and with the battery switch OFF, which CCR's begin the start up sequence and for how long?

Left CCR will begin start up sequence for 2-3 minutes, followed by the right CCR.

21

What is the cockpit indication when both CCR's are online?

All displays and HUD combiners show their default formats.

22

Which lights illuminate when STORM lights are selected on?

All illuminated indicator lights
Glareshield flood lights
Instrument panel flood lights
Aisle stand flood lights
Forward dome lights

23

Which individual lighting controls operate with the Master Brightness control systems?

All panel lights and displays
(Not dome lights, flood lights, area lights, HUD, standby compass, handset and annunciators)

24

Are the individual controls still effective when the master brightness system is working?

Yes, but only with limited adjustment capability.

25

If normal electrical power is lost, which lighting continues to operate?

-Standby electrical power is automatically provided to the primary displays.
-Aisle stand flood, forward panel flood, glareshield flood and dome lights illuminate automatically at a fixed brightness.

26

When the FASTEN SEAT BELTS sign is in auto, which conditions will illuminate the sign?

Landing gear not up and locked
Flap lever at 5 or greater
Airplane below an airline defined altitude
Cabin altitude above 10,000'
Passenger oxygen on

27

How many oxygen systems are fitted to the aircraft?

Two.
One for the flight deck and one for the passenger cabin.

28

Where is crew oxygen displayed?

Status display

29

What causes the passenger oxygen masks to deploy?
Automatically and manually?

Masks deploy automatically prior to:
-cabin altitude reaching 15,000'
-origin airfield altitude +2000'
-destination airfield altitude +2000'
Mask deploy manually by pushing the PASS OXYGEN switch ON.