07 Electrical Flashcards Preview

Boeing 777 CBT > 07 Electrical > Flashcards

Flashcards in 07 Electrical Deck (6)
Loading flashcards...
1
Q

With all electrical power turned OFF, the main battery can power which items through the hot battery bus?

A

1) engine fire extinguisher bottles,
2) APU fire extinguisher bottle, and
3) Air Data Inertial Reference Unit (ADIRU).

The ADIRU switch must be turned ON.

2
Q

The C2 TRU powers?

A

The First Officers flight instrument bus which also provides secondary DC power to the Captains instrument bus.

3
Q

At the gate with PRI EXT PWR ON, after APU start the APU will power?

A

L MAIN AC bus. The ELMS automatically switches the APU to power the L MAIN AC BUS and the PRI EXT PWR to power the R MAIN AC bus.

4
Q

With both PRI and SEC EXT PWR ON, which buses are powered?

A

The ELMS will normally switch the PRI EXT PWR to power the R MAIN bus and the SEC EXT PWR to power the L MAIN bus.

5
Q

Prior to engine shutdown with the PRI EXT PWR ON, no APU and no SEC EXT PWR what powers the main busses?

A

Selecting the PRI EXT PWR ON removes the IDGs, closes both busses and the PRI EXT PWR powers both L and R MAIN busses.

6
Q

What condition causes the IDG to disconnect automatically?

A

High IDG temperature. Most IDG faults require manual disengagement of the IDG.